
|
MiDaTek international
Hadstenvej 45
DK-8370 Hadsten
Denmark
+45 86982150
|
|
 |
 |
 |
Press release 14. July 2002
FAQ section is updated
Press release 26. June 2002 version 6.531
Support of 16 COM port's for all drivers.
Bitlink driver is updated
Press release 14. December 2001 version 6.525
Datalogfiles can now be formatted as HTML files, so they can be viewed with your internet
browser.
Press release 2. July 2001 version 6.521
Modicon TSX Modbus RTU PLC driver and generic
Modbus RTU driver for equipment supporting the Modbus protocol. All drivers are implemented in
the evaluation versions of ICE and DDEdrive.
Hotkey assignments of function keys to ICE HMI windows is added
Press release 12. Martz 2001 version 6.512
WM3-96 driver for Carlo Gavazzi Energy Management
Modular Power Analyzer, is implemented in the evaluation versions of ICE and DDEdrive.
Press release 14. February 2001 version 6.511
WM2-EM2 driver for Carlo Gavazzi Energy Management
Modular Power Analyzer, is implemented in the evaluation versions of ICE and DDEdrive. Driver
for the WM3-96 analyzer is currently under development.
Small additions and extensions to dynamic objects in ICE.
Press release 30. August 2000 version 6.506
New dynamic objects added, Windows checkbox, radio button and list box. Update performance from
PLC's has been improved.
Press release 19. April 2000 version 6.500
New and improved interface of MDraw and ICE. MDraw now implements floating toolbars that can
be configured by the developer. Menu bar and toolbar can be removed, giving nearly a full
screen display of HMI pictures. Moving bitmap objects, that can be changed/controlled from the
PLC.
Press release 21. February 2000
Siemens S7-200 driver, that uses the standard PPI programming
cable is now implemented in Industrial Control Environment and DDEdrive and is ready for
download with this driver included.
Press release 14. January 2000 version 6.130
Whole project's can now be exported from MDraw and zipped very easy with WinZip32. This makes
it very easy to move project's to other computers.
Press release 9. December 1999 version 6.127
Trend's is expanded to 8 pens and it is now possible to control all trend windows from one
trend menu. Trending in several windows can now be started and stopped globally from each
trend menu.
Press release 2. December 1999 version 6.125
BitLink driver supports the Bitlink company's own DLL driver if it is installed. Several
extensions to recipe handling.
Press release 22. November 1999 version 6.122
New Dynamic text object that displays text controlled by the PLC. Added feature for flashing
Lamp objects. The LED display object, now supports large 32 bit numbers. New project wizard
has been automated even further. Data logging can now be controlled by the PLC in all objects
that supports data logging
Press release 1. October 1999 version 6.120
Templates for defining the output format of log files. Tracking the highest and lowest value
into log files. Several objects now support this feature.
Press release 1. April 1999 version 6.101
ICE is now supporting wizards for creating new projects and saving the status of pictures to
open at startup. The interface now has flat style toolbars as in Win98.
Press release 10. Martz 1999 version 6.020
New powerful picture compiler and find/replace tags function, is now available in MDraw. The
compiler and the find/replace tags function can even dig down, replacing embedded tags in
files. These functions add to greater productivity and makes it easier to keep up your tags.
The compiler scans your picture for tags and assure that they exist in the
tag database. If a
tag in a picture is not found in the tag database, you will be presented for the object causing
the error.
MDraw will now send notifications to ICE whenever a picture or project changes.
The Bit Link FastLink ISA card driver is now supported
Press release 14. January 1999 version 6.012
New Order form object for production machines. This object can collect all sort of data from
several machines and print a report.
This type of machine normally has an item counter. Before starting a new order the counter is
preset to the number of items to produce. When the item counter reach the preset counter
value, the machine stops. The machine might have several stops during the production time. The
Order form can monitor the cause and the length of these stops times, and do a report
printout at the end of production. During production, pre-history stop causes can be viewed at
all times.
In the MDraw application, text objects now supports multiline text wrapping and a length of
250 chars.
Press release 30. November 1998 version 6.010
Additional options for log files is added. Now it's possible to do automated printouts
of log files once a day.
Press release 1. November 1998 version 6.000
With the introduction of the new version of Industrial Control Environment 6.0 to Windows
95-98 several functions is expanded
The new project based integrated environment gives you the power to manage several different
MMI/SCADA projects very easy. Each project can even be dialed up via modem once a day or on an
timed basis. This way data can be collected from several sites without the interference from
an operator.
The documentation generator takes care of the documentation of each project and picture for
you. When you have finished creating your MMI pictures your documentation is also ready to be
printed. No need to make that manually any more. Projects also contains version information,
so you can keep track of your project changes.
The log manager maintains operator access levels and passwords for each project.
Extended activity logging and project logging, that tracks what the operator is doing and the
values that the operator is changing in the PLC.
Data logging in columns
User defined symbols in different sizes
Trend curves with logging to disk and zoom function
and much, much more......
 |
|